LVS20 Vertical multicellular stainless steel in line pump
Application
- Transfer of liquids with low viscosity, non-flammable and non-explosive, not containing solid particles or fibers. These liquids must not chemically attack the materials of the pump.
- Water supply for tall buildings, pumping stations, overpressure in drinking water
- Washing stations, heating water circulation, air conditioning water circulation, water treatment systems
- Ultrafiltration, reverse osmosis, distillation systems, municipal swimming pools
- Irrigation: sprinkling, drip
- Food industry
- Fire fighting systems
Pump
- Liquid temperature: from -20°C to +120°C
- Nominal flow: 20 m³/h
- maximum pressure: 25 bars
- pH between 4 and 10
Motor
- IE3 motor
- Protection class: IP55
- Maximum ambient temperature: +40°
Identification codes
LVS
m
20
-10
-B
/F
DIN flange
inox 316 (by default, inox 304)
number of impellers
Nominal flow (m³/h)
Single-phase motor
Vertical multistage stainless steel in line pump
Technical data
Q (m³/h) | 4 | 8 | 12 | 16 | 20 | 24 | 28 | ||
---|---|---|---|---|---|---|---|---|---|
Model | kW | Q (l/min) | 67 | 133 | 200 | 267 | 333 | 400 | 467 |
LVSm20-1/F | 1.1 | H (m) | 13 | 13 | 13 | 12 | 10.5 | 9.5 | 6.5 |
LVS20-1/F | 1.1 | 13 | 13 | 13 | 12 | 10.5 | 9.5 | 6.5 | |
LVSm20-2/F | 2 | 28 | 28 | 27 | 25 | 22.5 | 19 | 15 | |
LVS20-2/F | 2 | 28 | 28 | 27 | 25 | 22.5 | 19 | 15 | |
LVS20-3/F | 4 | 43 | 43 | 42 | 39 | 36 | 30 | 23 | |
LVS20-4/F | 5.5 | 58 | 57 | 56 | 53 | 48 | 41 | 32 | |
LVS20-5/F | 5.5 | 73 | 72 | 70 | 66 | 60 | 52 | 40 | |
LVS20-6/F | 7.5 | 87 | 86 | 84 | 80 | 72 | 62 | 49 | |
LVS20-7/F | 7.5 | 102 | 100 | 97 | 93 | 84 | 72 | 57 | |
LVS20-8/F | 11 | 117 | 116 | 113 | 107 | 96 | 85 | 67 | |
LVS20-10/F | 11 | 146 | 144 | 140 | 132 | 120 | 105 | 83 | |
LVS20-12/F | 15 | MySQL User 'leopompevcmvc' has exceeded the 'max_questions' resource (current value: 64000) Query select capacity, height from productModeleTechnicalData where modeleRef = 'LVS20-12/F' order by capacity |