LVS5 vertical multistage stainless steel in line pump
Application
- Transfer of liquids with low viscosity, non-flammable and non-explosive, not containing solid particles or fibers. These liquids must not chemically attack the materials of the pump.
- Water supply for tall buildings, pumping stations, overpressure in drinking water
- Washing stations, heating water circulation, air conditioning water circulation, water treatment systems
- Ultrafiltration, reverse osmosis, distillation systems, municipal swimming pools
- Irrigation: sprinkling, drip
- Food industry
- Fire fighting systems
Pump
- Liquid temperature: from -20°C to +120°C
- Nominal flow: 5 m³/h
- maximum pressure: 20 bars
- pH between 4 and 10
Motor
- IE3 motor
- Protection class: IP55
- Maximum ambient temperature: +40°
Identification codes
LVS
m
5
-10
-B
/F(A, K, G)
DIN flange (oval, clamp fitting, threaded fitting)
inox 316 (by default, inox 304)
number of impellers
Nominal flow (m³/h)
Single-phase motor
Vertical multistage stainless steel in line pump
Technical data
Q (m³/h) | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 8.5 | ||
---|---|---|---|---|---|---|---|---|---|---|---|
Model | kW | Q (l/min) | 17 | 33 | 50 | 67 | 83 | 100 | 117 | 133 | 142 |
LVSm5-2 | 0.37 | H (m) | 13 | 12 | 12 | 10 | 9 | 7 | 6 | ||
LVSm5-3 | 0.55 | 19 | 19 | 18 | 16 | 15 | 12 | 10 | |||
LVSm5-4 | 0.55 | 26 | 25 | 24 | 22 | 19 | 16 | 14 | |||
LVSm5-5 | 0.75 | 33 | 32 | 30 | 28 | 24 | 22 | 18 | |||
LVSm5-6 | 1.1 | 40 | 38 | 37 | 34 | 28 | 27 | 23 | |||
LVSm5-7 | 1.1 | 46 | 45 | 42 | 40 | 32 | 32 | 27 | |||
LVSm5-8 | 1.1 | 53 | 51 | 48 | 45 | 40 | 36 | 31 | |||
LVSm5-9 | 1.5 | 60 | 59 | 56 | 53 | 47 | 44 | 37 | |||
LVSm5-10 | 1.5 | MySQL User 'leopompevcmvc' has exceeded the 'max_questions' resource (current value: 64000) Query select capacity, height from productModeleTechnicalData where modeleRef = 'LVSm5-10' order by capacity |